Ammonia solution 28,0 - 30,0% (NH₃ basis), AR Select® ACS for trace metal analysis, Macron Fine Chemicals™
Supplier: Avantor Performance Materials
|
Danger
|
Synonyms:
Ammonia aqueous, Ammonium hydroxide solution, Ammonium hydroxide, Ammonia water
Management of Change (MOC) category = N
MACR6665-46EA
0
SGD
MACR6665-46
MACR6665-14
MACR6665-18
Ammonia solution 28,0 - 30,0% (NH₃ basis), AR Select® ACS for trace metal analysis, Macron Fine Chemicals™
Ammonia solution
AR Select® - A line of acids specifically developed for trace metal analysis; analysed for up to 32 metals in the low ppb range.
Formula:
NH₃ MW: 35,05 g/mol Boiling Pt: 32…37,7 °C (1013 hPa) Melting Pt: –60…–57,5 °C Density: 0,88…0.91 g/cm³ (20 °C) Storage Temperature: Ambient |
MDL Number:
MFCD00066650 CAS Number: 1336-21-6 EINECS: 215-647-6 UN: 2672 ADR: 8,III |
Specification Test Results
Meets ACS Reagent Chemical Requirements | |
For Laboratory,Research,or Manufacturing Use | |
ACS - Assay (as NH₃) | 28.0 - 30.0 % |
Appearance | Passes Test |
ACS - Carbon Dioxide (CO₂) | ≤0.002 % |
ACS - Pyridine | Passes Test |
ACS - Residue after Ignition | ≤0.002 % |
ACS - Substances Reducing Permanganate | Passes Test |
ACS - Specific Gravity at 60°/60°F | 0.896 - 0.902 |
Trace Impurities - Arsenic (As) | ≤3.000 ppm |
Chloride (Cl) | ≤0.5 ppm |
Trace Impurities - Heavy Metals | ≤0.5 ppm |
Nitrate (NO₃) | ≤2 ppm |
Phosphate (PO₄) | ≤2 ppm |
Total Sulfur (as SO₄) | ≤2 ppm |
Determine by Flame Photometry & ICP - Aluminum (Al) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Barium (Ba) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Beryllium (Be) | ≤0.010 ppm |
Determine by Flame Photometry & ICP - Bismuth (Bi) | ≤0.010 ppm |
Determine by Flame Photometry & ICP - Boron (B) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Cadmium (Cd) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Calcium (Ca) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Chromium (Cr) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Cobalt (Co) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Copper (Cu) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Gallium (Ga) | ≤0.500 ppm |
Determine by Flame Photometry & ICP - Germanium (Ge) | ≤0.500 ppm |
Determine by Flame Photometry & ICP - Gold (Au) | ≤0.500 ppm |
Determine by Flame Photometry & ICP - Iron (Fe) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Lead (Pb) | ≤0.2 ppm |
Determine by Flame Photometry & ICP - Lithium (Li) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Magnesium (Mg) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Manganese (Mn) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Mercury (Hg) | ≤0.500 ppm |
Determine by Flame Photometry & ICP - Molybdenum (Mo) | ≤0.010 ppm |
Determine by Flame Photometry & ICP - Nickel (Ni) | ≤0.500 ppm |
Determine by Flame Photometry & ICP - Potassium (K) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Silicon (Si) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Silver (Ag) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Sodium (Na) | ≤0.500 ppm |
Determine by Flame Photometry & ICP - Strontium (Sr) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Thallium (Tl) | ≤0.050 ppm |
Determine by Flame Photometry & ICP - Tin (Sn) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Vanadium (V) | ≤0.010 ppm |
Determine by Flame Photometry & ICP - Zinc (Zn) | ≤0.100 ppm |
Determine by Flame Photometry & ICP - Zirconium (Zr) | ≤0.010 ppm |
Determine by Flame Photometry & ICP |
Learn more
About VWR
Avantor is a vertically integrated, global supplier of discovery-to-delivery solutions for...