Masterflex® L/S® MasterSense™ Fill/Finish Pump System with Masterflex® Ultrapharm™ Pump Head

Accuracy is critical when every drop counts

Masterflex® L/S® MasterSense™ Fill/Finish Pump System with Masterflex® UltraPharm™ Pump Head

Shop now

Features that make your process effortless

1

Perfect for sanitary environments—
316 polished stainless steel drive housing, IP66 and NEMA 4X rated for washdown

2

Easy to read and operate touch screen - even while wearing gloves. Create, save, and recall pump programs via intuitive menus.

3

EtherNet/IP, Profibus, Wi-Fi, MasterflexLive enabled, and analog remote I/O means connectivity and control options that suit your needs.
LEARN MORE

4

250 rpm max speed; dosing volumes from <0.5 mL to >500 mL
VIEW SPECS

Masterflex L/S MasterSense Precision fill-finish pump system
5

Whisper quiet operation reduces extra noise on the floor or in the lab

6

316 stainless steel pump head is autoclavable; tested to 10 cycles without any loss of flow or accuracy performance

7

Offset rollers and planetary gearing ensure dosing accuracy (±0.5%), low pulsation, and long tubing life
Easy on tubing— reduces drag on tubing for longer tubing life and reduced risk of premature failure.

8

Masterflex double-Y tube sets ensure proper retention, repeatability, and accuracy
SHOP DOUBLE Y-TUBING

Masterflex Mastersense BT BioPharma Touchscreen

Continous Mode

Masterflex Mastersense BT BioPharma Touchscreen

Time Mode

Masterflex Mastersense BT BioPharma Touchscreen

Volume Mode

Masterflex Mastersense BT BioPharma Touchscreen

Remote Mode

Masterflex Mastersense BT BioPharma Touchscreen

Tube Calibration

Masterflex Mastersense BT BioPharma Touchscreen

User Access

Benefits of a Pump Head with Planetary Drive System

With the planetary drive system, each roller is directly driven by the sun wheel. This mechanism prevents axial push-pull friction on the tubing—resulting in longer tubing life, lower pulsation, and high repeatability.

This pump head produces gentle, low pulse, and highly accurate dosing and flow to ensure optimal integrity and uniformity. Designed with offset rollers, the pump head provides linear flow throughout the flow range. While one roller is drawing fluid through one leg of the double-Y tube set, the other roller is pushing fluid through the other leg. Also, dual channels allow for a lower rpm in order to achieve “single-channel” flow rates. A lower rpm means reduced shear forces to maintain fluid and molecular integrity.

intuitive touchscreen works even wearing gloves

Set up is a breeze

Intuitive touch screen interface, even wearing gloves

  • Easy to set up and program
  • 5" capacitive TFT/RGB touch screen with a clear, wide viewing angle
  • Adjust parameters with a simple touch—even with gloves on
  • Operational modes include continuous run, volume dispense, and time dispense
  • Batch control and interval/off time in Volume and Time modes
  • Antidrip and speed ramping available in Volume mode—ensure accuracy and minimize sample loss
  • Easily save and recall up to 50 commonly used protocols, each with a unique name
  • Know when you hit your mark—graphical indicator lets you know when loaded tubing is optimally calibrated

Advanced Connectivity and Control Options

Monitor from anywhere

MasterflexLive Remote Pump Monitoring

MasterflexLive

  • MasterflexLive is our secure, cloud-enabled platform for real-time remote monitoring of all Masterflex pump parameters
  • Monitor critical processes running 24/7 without the need for onsite personnel
  • Push notifications alert you to changes in operating conditions and error messages

Learn more

Flexible Connectivity

  • Your choice of connectivity options— EtherNet/IP, Profibus, or MasterflexLive®
  • Three-tier access to pump functionality—use this option to protect your process by controlling who can operate the pump and at what level
  • Over-the-air firmware updates—automatically allows you to take full advantage of future enhancements
  • Internet connection via Wi-Fi or standard Ethernet (RJ45) jack on rear of drive

See full specifications

The Perfect Pump for High Precision Fill/Finish Applications

Biopharma

Non-contaminating, low shear, and noninvasive makes this pump perfect for Biopharma and healthcare.

vaccine production line

Three-tier access and the ability to save and recall programs make your fluidic process secure and accurate.

custom cut tubing

Our range of tubing formulations ensures the fluid compatibility and the regulatory approvals you need.

Water treatment process

Precision manufactured pump tubing gives you accuracy and reliability for critical process applications.

Complete Specifications & Product Details

  Masterflex L/S MasterSense Fill/Finish pump system Masterflex L/S MasterSense Fill/Finish pump system
Item # MFLX77976-40 MFLX77976-42
Flow Range 0.007 to 635 mL/min 0.193 to 998 mL/min
Masterflex Ultrapharm Pump Head for Precision Tubing with Open-Head Sensor, stainless steel housing/rotor for High-Performance Precision Tubing with Open-Head Sensor, stainless steel housing/rotor
Tubing sizes accepted Double-Y L/S® 13, 14, 16, 25, 17 Double-Y L/S® 15, 24, 35

Pump Specifications

Agency Approvals UL, cUL, CE
Speed control accuracy (resolution) ±0.1% (0.1 rpm at 250 rpm)
Warranty 2 Year
MasterflexLive Real-time remote monitoring of all pump parameters. Push notifications alert you to operating conditions and error messages, allowing you to monitor critical pump processes 24/7—no need to be onsite.
EtherNet/IP or
Profibus
Interface directly with either Ethernet/IP or Profibus based process control network(s) (using PLC, SCADA or similar); enables control of all pump parameters via network interface.
Number of rollers 8
Reversible Yes
Display 5” capacitive TFT/RGB touch screen with in-plane switching (wide viewing angle); 800 x 480 pixels
Digital Dispensing Yes
External control - input 0 to 20 mA, 20 to 0 mA, 4 to 20 mA, 20 to 4 mA; 0 to 10 V, 10 to 0 V, 0 to 5 V, 5 to 0 V; start/stop, direction (CW/CCW), prime via contact closure
External control - output 0 to 20 mA, 20 to 0 mA, 4 to 20 mA, 20 to 4 mA; 0 to 10 V, 10 to 0 V, 0 to 5 V, 5 to 0 V; Tach output (open collector), Motor running, Open head, Local/Remote, General alarm
Motor Brushless DC with encoder; continuous duty; reversible; 1/10 hp (75 W)
Open-head sensor Yes; extension cable included
Housing materials 316 Stainless Steel
Enclosure rating IP66 / NEMA 4X
Dimensions (L x W x H) 13" x 9.3" x 11" (33 x 23.6 x 27.9 cm)
Shipping weight 40.75 lb (18.5 kg)
Power 90 to 260 VAC, 50/60 Hz

Double-Y Tube Sets for the Masterflex® UltraPharm™ Pump Head