You Searched For: Multi-Element Standards


17,907  results were found

SearchResultCount:"17907"

Sort Results

List View Easy View (new)

Rate These Search Results

Catalog Number: (MANA945604)
Supplier: MACHEREY-NAGEL
Supplier Article Number:: 945604
Description: Test kit, BioFix® Lumi diluent for solid phase test, BioFix®
UOM: 1 * 1 L

MSDS


Catalog Number: (AXYGMAG-DYECL-1)
Supplier: Corning
Supplier Article Number:: MAG-DYECL-1
Description: Removing excess dye terminator is an essential step prior to Sanger sequencing. Carryover of the excess dye into the sequencing reactions may result in dye blobs resulting in inaccurate results. The AxyPrep™ Mag DyeClean kit utilises a paramagnetic bead-based purification system for Sanger sequencing reaction dye terminator clean-up. The protocol is simple and comprises binding, washing and elution steps which can be performed directly in the thermal cycling plate. This kit requires no centrifugation or filtration steps.
UOM: 1 * 1 items

Catalog Number: (AXYGMAG-FRAG-I-1)
Supplier: Corning
Supplier Article Number:: MAG-FRAG-I-1
Description: The AxyPrep™ FragmentSelect-I Kit is optimized for Illumina next generation sequencing platforms and Life Technologies (SOLiD) fragment size selection needs to simplify the library construction workflow. The kit is designed for fragment size selection needs in the Roche/454’s DNA Genome sequencer library construction workflow.
UOM: 1 * 1 items

Catalog Number: (GRANES-80)
Supplier: GRANT INSTRUMENTS
Supplier Article Number:: ES-80
Description: Robust and reliable shaker incubator with programmable time, temperature and shaking speed. This unit is ideal for gentle or vigorous mixing and incubation of samples in a variety of flasks and vessels. The ES-80 features soft stop and start to protect samples, it has a stainless steel inner chamber. The unit is suitable for applications including cultivation of microorganisms and cells, long term growth projects, tissue sample extraction at temperatures up to 80 °C.
UOM: 1 * 1 items


Supplier: MP Biomedicals
Description: Agar is a polysaccharide complex extracted by bleaching and hot water treatment of agarocytes from the red alga Rhodophyceae, and usually consisting of the genera Gelidium, Acanthopeltis, Ceramium, Pterocladia and Gracilaria. The algae are typically found in the Pacific and Indian Oceans and in the Sea of Japan. It is primarily composed of two different units: Agarose and Agaropectin; Agarose is a neutral gelling component which is composed of a linear polymer of alternating D-galactose and 3,6-anhydrogalactose units. Agaropectin is a non-gelling component which consists of D-1,3-glycosidically linked D-galactose units, some of which are sulfated at the 6th position.
Agar is specially purified for use in preparing solid culture media for microbiological and bacteriological applications.

Catalog Number: (EPPE0030129.571)
Supplier: EPPENDORF
Supplier Article Number:: 0030129.571
Description: Eppendorf twin.tec® PCR plates combine extremely thin walled polypropylene wells for optimal heat transfer to the sample and robust polycarbonate frames for ultimate rigidity and torque-resistance. Eppendorf twin.tec® plates reduce the risk of cross contamination with raised well rims for effective sealing.
UOM: 1 * 300 items

Environmentally Preferable


Supplier: VWR Collection
Description: Digital shaker with microprocessor control which is ideal for mixing applications with heavy loads, e.g., cell cultures, solubility studies and extraction procedures. Variable speed control provides consistent, uniform shaking action. The Accu-drive shaking system delivers exceptional speed control, accuracy, safety and durability, the system continuously monitors shaking speed and will maintain set point even under changing loads.

Catalog Number: (ICNA0202809)
Supplier: MP Biomedicals
Supplier Article Number:: 0202809
Description: MP EcoChrom™ SILICA is used as a suspending and thickening agent in pharmaceutical.A silica-based aerogel was used in the Stardust spacecraft to collect extraterrestrial particles. Silica is also used in the extraction of DNA and RNA due to its ability to bind to the nucleic acids under the presence of chaotropes. As hydrophobic silica it is used as a defoamer component. In hydrated form, it is used in toothpaste as a hard abrasive to remove tooth plaque. SiO2 has a number of distinct crystalline forms (polymorphs) in addition to amorphous forms. In the majority of silicates, the Si atom shows tetrahedral coordination, with 4 oxygen atoms surrounding a central Si atom.

MP EcoChrom™ Silica, the chemical compound silicon dioxide, also known as silica (from the Latin silex), is an oxide of silicon with the chemical formula SiO2 with a mean pore size of 60Å and particles size of 200-500μm. MP silica are free of particles outside the standard range. The irregular shape of MP Silica permits the easy packing of column permeability and plate number. They allow easy switching from one sieve cut to another, offering an easy way to change the chromatographic methods. It has been known for its hardness since ancient times. Silica is most commonly found in nature as sand or quartz, as well as in the cell walls of diatoms.
UOM: 1 * 25 kg


Supplier: Brand
Description: PS, solid or with transparent base. These flat bottom plates are available in different colours, and with standard or transparent base formats.

Supplier: MACHEREY-NAGEL
Description: Thin-layer chromatography plates (TLC), POLYGRAM®, POLYGRAM® TLC polyester sheets Alox N/UV254, Coating material: Aluminium oxide (Alox), Backing material: Polyester, Fluorescent indicator: F254, Plate size: 40×80 mm

Supplier: VWR Collection
Description: Digital shakers with microprocessor control which are ideal for mixing applications with heavy loads, e.g. cell cultures, solubility studies and extraction procedures. Variable speed control provides consistent, uniform shaking action. The Accu-drive shaking system delivers exceptional speed control, accuracy, safety and durability, the system continuously monitors shaking speed and will maintain the set point even under changing loads.

Supplier: VWR Collection
Description: Digital shaker with microprocessor control which is ideal for a range mixing applications, e.g. cell cultures, solubility studies and extraction procedures. Variable speed control provides consistent, uniform shaking action. The Accu-drive shaking system delivers exceptional speed control, accuracy, safety and durability; the shaking system continuously monitors shaking speed and will maintain the set point even under changing loads.

Supplier: Brand
Description: PS, solid or with transparent base. Plates are available with different well shapes (round U-bottom, conical V-bottom, flat F-bottom or flat C-bottom with curved edges), in different colours, and with a choice of cell culture treated surfaces.

Supplier: Metro International
Description: Shelves, Mobile post, SiteSelect™, chrome plated, 1385 mm height, For: Drop Mat™ Super Erecta® display shelving, Super Adjustable Super Erecta® shelving, Super Erecta® shelving, Super Erecta® Solid shelving, APPEAL™ display shelving

Supplier: MP Biomedicals
Description: Preparation Method: MP Intrinsic Factor is produced from the pylorus mucous membrane of the pig, of which only a small part is used. Only the part which, according to histological examinations has proved to have a high content of Intrinsic Factor, is used.
Applications: Intrinsic Factor is used in the treatment not only of classical pernicious anaemia, but also in the treatment of other macrocytic anaemias, where it replaces the Intrinsic Factor which may be lacking in the patient's own gastric juice. In this way Intrinsic Factor is recommended against anaemias that appear 6 to 12 months after serious gastric operations, and against anaemias that are secondary effects of the treatment with certain medicines, e.g. against epilepsy. However, the dietetic use in multi-vitamin preparations is of the greatest importance. In older people there has been observed a degeneration of the gastric mucous membrane, whose secretion of Intrinsic Factor is insufficient to ensure the resorption of the necessary quantity of B-12 from their diet. In order to delay this development it is useful to prescribe a small quantity of Intrinsic Factor with B-12 and other vitamins to these patients.
Product Description: Intrinsic factor is a glucoprotein extracted from the pylorus part of the gastric mucous membrane. Its presence is considered necessary for the absorption of Vitamin B-12.
Unit Definition: The activity is normally indicated in Coli units, the number of which are proportional to the binding power of the substance to Vitamin B-12.

Application Areas: Absorption of vitamin B12
Product Type: Proteins, Enzymes & Peptides
Presentation: Tan Powder
Foreign activity: Salmonella=Negative, E. coli=Negative
NOTES: Standard Plate Count <1000/g
Solubility: Slightly soluble in toluene; practically insoluble in water.
Storage & Handling: -20°C

Supplier: MACHEREY-NAGEL
Description: Unmodified standard silica layers for TLC.

Inquire for Price
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at +65 6505 0760.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at +65 6505 0760.
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR at sales@sg.vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
This product has been blocked by your organization. Please contact your purchasing department for more information.
The original product is no longer available. The replacement shown is available.
This product is no longer available. Alternatives may be available by searching with the VWR Catalog Number listed above. If you need further assistance, please call VWR Customer Service at +65 6505 0760.
1 - 16 of 17,907
no targeter for Bottom